October 2024

ALPHABET SOUP

REVIEWING THE OPTIONS

ISOLITE

ALPHABET SOUP: REVIEWING THE OPTIONS

Chalk Talk

Exit sign / EM Light Options

- Alphabet Soup

- Defining Some Options

- An example

Inverter Options

- Inverter Soup

- Defining the Options

- Inverter Example

Resources

- New cheat sheet

- Spec sheets

UNDERSTANDING OPTIONS

OVERVIEW

EXIT SIGNS & EM LIGHTS

INVERTERS

MARKETING AND SALES

NAVIGATING THE SPEC SHEET

EXIT SIGNS

EXIT SIGNS

Ordering Information

1. SERIES

ELT2

2. OPERATION

AC   AC Only

EM  Ni-Cad Battery Backed

3. LETTER COLOR

G   Green

G8  Green 8" Letter

R   Red

R8  Red 8" Letter

4. FACE COUNT

1C   Single Face, Clear Background

1M   Single Face, Mirror Background

1W   Single Face, White Background

2M   Double Face, Mirror Background

2W  Double Face, White Background

5. FRAME STYLE

AG   Angular Trim

FT   Flat Trim (1)

1.  Only available with recessed mount.

6. FRAME COLOR

BA   Brushed Aluminum

BK   Black

BR   Painted Brass

WH   White

CC   Custom Color

8. CHEVRON

AB   Double Arrow

AL   Arrow Left

AN   No Arrows

AR   Arrow Right

AL   Right & Left Arrow (Double Face Only)

AU   Universal Chevron Kit

7. MOUNTING

MRC   Recessed Ceiling Mount

MT   Top Mount

MB   Back Mount

ME   End Mount / Side Mount

MPA   12" Pendant Mount

MPB   24" Pendant Mount

MPC   36" Pendant Mount

MPD   48" Pendant Mount

MPE   60" Pendant Mount

MTEB   Top / End / Back Mount

MMT   Mullion Mount Top

MMB   Mullion Mount Bottom

MRCLB   Recessed Ceiling Mount, Preship Backbox (2)

9. OPTIONS

BLANK = NO OPTION

CX   Dual Circuit - Universal Voltage

SD   Self-Diagnostics (EM Only)

SR   Self-Diagnostics + IR Remote Testing Receiver (EM Only)

VF   Other Input Voltage (Indicate Volt & Frequency)

FL   Flasher

FA   Fire Alarm Interface

FLA   Flasher / Audible Alarm

FAA   FA Option w/Audible Alarm

DL   Damp Location Listed

OW   Old Work Clips (1)

ORDERING NOTES

1. Only available with recessed mount.

2. Must order ELT2-ACCY-RBB with MRCLB option

ELT2-AC-G-1C-AG-BA-MB-AB

Ordering Information

EXIT SIGNS

EXIT SIGNS

1. SERIES

ELT2

2. OPERATION

AC   AC Only

EM  Ni-Cad Battery Backed

3. LETTER COLOR

G   Green

G8  Green 8" Letter

R   Red

R8  Red 8" Letter

4. FACE COUNT

1C   Single Face, Clear Background

1M   Single Face, Mirror Background

1W   Single Face, White Background

2M   Double Face, Mirror Background

2W  Double Face, White Background

5. FRAME STYLE

AG   Angular Trim

FT   Flat Trim (1)

1.  Only available with recessed mount.

6. FRAME COLOR

BA   Brushed Aluminum

BK   Black

BR   Painted Brass

WH   White

CC   Custom Color

8. CHEVRON

AB   Double Arrow

AL   Arrow Left

AN   No Arrows

AR   Arrow Right

AL   Right & Left Arrow (Double Face Only)

AU   Universal Chevron Kit

7. MOUNTING

MRC   Recessed Ceiling Mount

MT   Top Mount

MB   Back Mount

ME   End Mount / Side Mount

MPA   12" Pendant Mount

MPB   24" Pendant Mount

MPC   36" Pendant Mount

MPD   48" Pendant Mount

MPE   60" Pendant Mount

MTEB   Top / End / Back Mount

MMT   Mullion Mount Top

MMB   Mullion Mount Bottom

MRCLB   Recessed Ceiling Mount, Preship Backbox (2)

9. OPTIONS

BLANK = NO OPTION

CX   Dual Circuit - Universal Voltage

SD   Self-Diagnostics (EM Only)

SR   Self-Diagnostics + IR Remote Testing Receiver (EM Only)

VF   Other Input Voltage (Indicate Volt & Frequency)

FL   Flasher

FA   Fire Alarm Interface

FLA   Flasher / Audible Alarm

FAA   FA Option w/Audible Alarm

DL   Damp Location Listed

OW   Old Work Clips (1)

ORDERING NOTES

1. Only available with recessed mount.

2. Must order ELT2-ACCY-RBB with MRCLB option

ELT2-AC-G-1C-AG-BA-MB-AB

EXAMPLE

HOW IT WILL LOOK

HOW IT WILL INSTALL

HOW IT WILL OPERATE

HOW IT CAN BE ORDERED

SIMPLIFYING THINGS

- No battery (for use with inverter)

DEFINING OPTIONS

- Battery Backup

- Two AC circuits, one from utility, one from inverter/generator

AC Only - AC

EM

Dual Circuit - CX, C1, C2

EXIT SIGNS & EMERGENCY LIGHTS

ORDERING NOTES

1. This dual circuit option should only be used for exits that are intended to be connected simultaneously to normal and emergency power circuits but cannot support hot inputs. Only one of the normal or emergency circuits can be powered at any given time. Energizing both normal and emergency circuits simultaneously will result in damage to the exit sign.

ISOLITE

ALPHABET SOUP: REVIEWING THE OPTIONS

Chalk Talk

- Automatically tests every 28 days

DEFINING OPTIONS

- Remote to initiate test from the ground

- Battery will last longer than 90 minutes

- Able to share its battery with a "remote" fixture

Self-Diagnostic - SD

IR Receiver - SR/TLRT

Extended Runtime - EB

Remote Capacity - EB

EXIT SIGNS & EMERGENCY LIGHTS

ISOLITE

ALPHABET SOUP: REVIEWING THE OPTIONS

Chalk Talk

- Flashes the legend in emergency mode

DEFINING OPTIONS

EXIT SIGNS & EMERGENCY LIGHTS

- Buzzes in emergency mode

- Flashes legend when the fire alarm goes off

- Turns on lights

Flasher - FL

Audible Alarm - FLA

Fire Alarm Interface - FA

ISOLITE

ALPHABET SOUP: REVIEWING THE OPTIONS

Chalk Talk

- Often includes flasher

- Impact resistant bubble to protect the device

DEFINING OPTIONS

- Security torx screws

When you'd want these:

- High-traffic environments

- Schools and gyms

- Prisons and mental health facilities

- Public spaces like train stations

Vandal Shield - VR

Tamperproof Screws - TP

EXIT SIGNS & EMERGENCY LIGHTS

ISOLITE

ALPHABET SOUP: REVIEWING THE OPTIONS

Chalk Talk

- Heated battery for cold applications

DEFINING OPTIONS

- Extends warranty on electronics from 5 years to 10 years

- Print almost any words / graphics onto an exit sign

Heater - HX, H1, H2

Extended Electronics Warranty - EEW

Custom Wording - CW

EXIT SIGNS & EMERGENCY LIGHTS

- Keeps emergency lights on for 15 minutes after power is restored

- For ballast restrike on sodium lights

Time Delay - TD

ISOLITE

ALPHABET SOUP: REVIEWING THE OPTIONS

Chalk Talk

- A historic stone building with a courtyard

The Application

EXAMPLE

EXIT SIGNS

Needs to:

- Match the aesthetic

- Connect to fire alarm

- Wire without a back box

- Stand up to weather

ISOLITE

ALPHABET SOUP: REVIEWING THE OPTIONS

Chalk Talk

Specifying the Sign

EXAMPLE

EXIT SIGNS

ISOLITE

ALPHABET SOUP: REVIEWING THE OPTIONS

Chalk Talk

Ordering Information

1. SERIES

LPDC2

2. OPERATION

AC   AC Only

EM  Battery Backed

3. LETTER COLOR

R   Red

G  Green

4. FACE COUNT

1   Single

2   Double

U  Universal

5. BODY COLOR

WH  White

BK   Black

CC   Custom

6. FACE COLOR

BA   Brushed Aluminum

WH  White

BK   Black

CC   Custom

7. MOUNTING

MTEB   Mount Top End Back

MB   Back Mount

ME   End Mount

MS   Stanchion Mount

MCE   Direct Conduit Entry

MPA/B/C/D/E/F   Pendant Mount

8. OPTIONS

HX   Heater/Cold Temp.

CX   Dual Circuit

DL   Damp Location

FA   Fire Alarm Interface

FL   Flasher

SD   Self-Diagnostic/IR Receiver

VR   Vandal Shield

TP   Tamperproof Screws

LW   Wet Location

EEW   Extended Electronics Warranty

Brown

EXAMPLE

EXIT SIGNS

ISOLITE

ALPHABET SOUP: REVIEWING THE OPTIONS

Chalk Talk

INVERTER OPTIONS

INVERTERS

More Alphabet Soup...

ISOLITE

ALPHABET SOUP: REVIEWING THE OPTIONS

Chalk Talk

9. OPTIONS

BLANK = NO OPTION

MB   Maintenance Bypass Switch

CB   Custom Breaker

DT   Delayed Transfer

EMW20   Extended Battery Warranty

EEW   Extended Electronics Warranty

ORDERING NOTES

1. In order to use the web-based monitoring available at Isolite.com, the -WEB option must be selected.

2. Indicated VA ratings may be ordered as a stacked unit using Configuration H. This configuration is not seismic certified. Contact factory for specific details.

KE   Keyed Enclosure

TA   Trip Alarm with Breaker

RA   Remote Annunciator (Not included with TB)

TB   Programmable Terminal Block (Not included with RA)

Z4   Seismic Zone 4 Restraints (Includes KE)

BI   BMS Integration

BTMS   Battery Thermal Management System

EO   Emergency Power Off

WEB   Web Monitoring Connection (1)

LO  Breaker Locks

NOTES

Maximum number of OUTPUT breakers supported depends on sizing and option selection. Contact factory for specific details.

Disconnects all inverter electronics but allows all the lights downstream of the inverter to remain on

DEFINING OPTIONS

INVERTERS

Maintenance Bypass Switch - MB

- This allows you to work on the inverter without effecting lighting in the building

- Note that this option may impact number of breakers

ISOLITE

ALPHABET SOUP: REVIEWING THE OPTIONS

Chalk Talk

Output breakers of unique amperage/voltage

Custom Breaker - CB

- Amperages like 50A or 10A (standard is 20A)

- 2-pole breakers on a 3-phase inverter

For example:

The inverter sends info to a Building Management System via a wired connection

DEFINING OPTIONS

INVERTERS

BMS Integration - BI

- The data points it sends are published on "BMS Interface Points List"    on the spec sheet

Access critical data from the inverter through the internet

Web Monitoring Connection - WEB

- This is a free option

ISOLITE

ALPHABET SOUP: REVIEWING THE OPTIONS

Chalk Talk

This option allows you to integrate a building management system or fire alarm system

DEFINING OPTIONS

INVERTERS

Programmable Terminal Block - TB

LED and buzzer alarm that is mounted remotely from the inverter

Remote Annunciator - RA

- The relay can be triggered on the following status or alarm features:

- Field-selectable wet or dry contacts

- Useful for when the inverter is locked away in an electrical closet or basement where its own alarm can't be heard

ISOLITE

ALPHABET SOUP: REVIEWING THE OPTIONS

Chalk Talk

- AC Present

- Battery Charging

- Inverter On

- High Temperature

- Utility Failure

- Near Low Battery

- Low Battery

- High VAC

- Low VAC

- Relay Off

Breaker with built-in alarm to alert when it trips

DEFINING OPTIONS

INVERTERS

Trip Alarm with Breaker - TA

Allows breakers to be locked in the off position

Breaker Locks - LO

- Produces a loud sound when tripped

- Alerts Web Monitoring System

- Takes up 1.5 breaker spaces

- For OSHA Lockout / Tagout: a safety procedure that keeps equipment off and prevents it from being       turned back on while maintenance or repairs are being done downstream..

ISOLITE

ALPHABET SOUP: REVIEWING THE OPTIONS

Chalk Talk

DEFINING OPTIONS

INVERTERS

- Extends the prorated battery warranty schedule to 20 years

Extended Battery Warranty - EMW20

- Extends the electronics warranty from 3 years to 5

Extended Electronics Warrenty - EEW

ISOLITE

ALPHABET SOUP: REVIEWING THE OPTIONS

Chalk Talk

- Locks the inverter to prevent tampering

Keyed Enclosure - KE

Adds brackets and bracing to prevent damage in an earthquake

- Meets OSHPD Zone 4 certification

DEFINING OPTIONS

INVERTERS

Seismic - Z4

The inverter kicks on less quickly to allow smart power packs to detect an outage

Delayed Transfer - DT

A big red button that kills power to everything

- External to the unit

Emergency Power Off - EO

A more advanced temperature reading configuration that measures temperature at the busbar between every two batteries.

Battery Thermal Management System - BTMS

ISOLITE

ALPHABET SOUP: REVIEWING THE OPTIONS

Chalk Talk

- A new construction high rise in California needs         emergency lighting.

The Application

EXAMPLE

INVERTERS

- Limited space in electrical closet

- 26kVA load

- Tenant is a financial institution

ISOLITE

ALPHABET SOUP: REVIEWING THE OPTIONS

Chalk Talk

Details:

EXAMPLE

INVERTERS

ISOLITE

ALPHABET SOUP: REVIEWING THE OPTIONS

Chalk Talk

9. OPTIONS

BLANK = NO OPTION

MB   Maintenance Bypass Switch

CB   Custom Breaker

DT   Delayed Transfer

EMW20   Extended Battery Warranty

EEW   Extended Electronics Warranty

ORDERING NOTES

1. In order to use the web-based monitoring available at Isolite.com, the -WEB option must be selected.

 

KE   Keyed Enclosure

TA   Trip Alarm with Breaker

RA   Remote Annunciator (Not included with TB)

TB   Programmable Terminal Block (Not included with RA)

Z4   Seismic Zone 4 Restraints (Includes KE)

BI   BMS Integration

BTMS   Battery Thermal Management System

EO   Emergency Power Off

WEB   Web Monitoring Connection (1)

LO  Breaker Locks

NOTES

Maximum number of OUTPUT breakers supported depends on sizing and option selection. Contact factory for specific details.

MB-CB-DT-EMW20-EEW-TA-RA-Z4-BI-BTMS-EO-LO

E3MAX-33000-3P-LC-IF-OF/OG-C18

- Specs Sheets & Drawings

- New cheat sheet

Available on the Website

- Training Video Link

- Sales Presentation PDF

- Sell Sheet & Marketing Assets

Available Within Follow-Up Sales Packet

SALES MATERIALS

SUPPORT

ISOLITE

PRODUCT OPTIONS

Chalk Talk

NEED FURTHER ASSISTANCE?

SUPPORT

- Schedule a Webinar for Advanced Sales & Engineering Training

Team of Experts

ISOLITE

PRODUCT OPTIONS

Chalk Talk

For Additional Training, Please Contact Your

Local Sales Representative

THANK YOU